Loop Avoidance/Transit Counter

General

-

Prerequisites

Loop avoidance is used in DPNSS networks.

Transit counter is used in ISDN and H.323 networks.

Execution

The maximum number of transit exchanges a call can be routed through in order to reach the final destination is set in D 14 and D 15 of the ADC parameter in the command RODDI.