Conferenced

The Conferenced event indicates that the conferencing device has conferenced itself or another device with an existing call and that no devices have been removed from the resulting call.

Transfer calls to an intruded conference or a conference will not result in a transferred event. It will cause a conferenced event with the transferred party as an added party.

Clear Connection will remove the transferring party from the conference.

Event Parameters

Table 1. Event parameters

Parameter

Type

Description

monitorCrossRefID

MonitorCrossRefID

Associates the event to existing monitor.

primaryOldCalll

ConnectionID

The connectionID of the primary call.

secondaryOldCalll

ConnectionID

The connectionID of the secondary call. Always present when fixed view is used. If local view is used included when there are two known calls at the monitored device before the conference is created.

conferencingDevice

SubjectDeviceID

The conferencing device.

addedParty

SubjectDeviceID

The added device.

conferenceConnections

ConnectionList

Information about each device/ConnectionID in the resulting conference call.

localConnectionInfo

LocalConnectionState

Local connection state of the device associated with the monitor cross reference ID. Only included for device monitors.

correlatorData

CorrelatorData

The correlator data associated with the call.

Cause

EventCause

The reason for the event.

Event Causes

The default cause is Conference; other possible value is:
  • Override