OPNEE

Operator notified exchange end

Format

OPNEE:NEXGNO=[,OWNID=];

NEXGNO =

Notified exchange number.

An exchange number for exchanges, which are to be notified of day or night-status changes in the centralized PBX operator's exchange.

& is permitted for this parameter.

OWNID =

Own exchange number.

An exchange number which should be the own exchange number of the centralized PBX operator's exchange, and is used as A-number in day or night status notification calls. Only one number can be set. The parameter may not be omitted if the own exchange number for the exchange was previously set.

Function

The command is used to remove one or several exchange numbers from the table, which gives the information about the exchanges that are to be notified of day or night-status changes in the centralized PBX operator's exchange. It is also used to remove the own exchange number used as A-party number in day or night status notification calls.

Example

Remove the exchanges with exchange numbers 742 and 764 from the table of exchanges, that are to be notified of day or night-status changes in a centralized PBX operator's exchange. Keep the own exchange number.

OPNEE:NEXGNO=742&764;

EXECUTED

Command Category

Dangerous = No