Web Interface
To configure and manage the MGU3 board using the Web Interface:
-
Connect the MGU3 board to the network.
- When the board connects to the network for the first time, it will attempt to obtain an IP address from a DHCP server.
- If no IP address is assigned, the board will default to 192.168.1.2/24.
-
Open a web browser and enter the following to access the Web Interface.
http://<IP address> -
Login to the Web Interface using the following default credentials.
- Username:
admin - Password:
admin
- Username:
-
After logging in for the first time, immediately change the default password to a preferred secure password (Mandatory on First Login).
-
If required you can enable SSH remote access. (Optional)Note: For security reasons, SSH access is disabled by default.
Board Configuration Tasks
From the web interface, you can perform the following actions:
- Change the Admin and Root Passwords
- Configure the Board IP Address
- Change the Board Host Name
- Monitor Board Status
- Take Trace/Logs for Troubleshooting
- Enable/Disable SCTP over UDP
↑