Event log

The last 254 event messages are listed here.

Event messages have a certain severity level: Normal, Serious and Critical. Many event messages have both a negative impact (error occurred) and a positive impact (error corrected). Some event messages have no impact and, thus, no match. Severity level, positive or negative impact (if any) and the information, if there is a match or not, are indicated in the event table.

If an SRM server is indicated as signal destination, the event message severity level results in a change of system status. This can be seen in the SRM agent and is displayed with the corresponding colour (see section "SRM destination").

In the table below all possible event messages are listed with the activation conditions and detailed information on the parameters.

Table 1. Event types, in alphabetical order

Event message

Trigger condition

Details1

Severity

ATAS: Connection established

ATAS: connection (re) established

Date, time

critical (positive, with match)

ATAS: Connection lost

ATAS: connection lost

Cause (0: Logoff, 1: missing cycle signal), date, time

critical (negative, with match)

BluStar Client back within the licence limit

A sufficient number of licences is now available again for BluStar clients.

Parameter 1: 0 (not used)

Licence type: 0 and 1: (not used), 2: BluStar CTI, 3: BluStar Softphone, 4: BluStar Video option, 5: BluStar Presence option

Parameter 1, licence type, total purchased licences, date, time

Serious (positive, with match)

Card in service

A card that was previously out of service is back in service again.

Number of the expansion slot, date, time

critical (positive, with match)

Card out of service

A card previously in operation has stopped functioning.

Number of the expansion slot, date, time

critical (negative, with match)

Card reset

A reset was carried out for one card

Number of the expansion slot, date, time

Serious (without match)

Charge counter overflow

Individual cumulative counter or cost centre counter overflow

Cause (0: User / 1: Cost centre / 2: Exchange line / 3: Room), number, date, time

Serious (without match)

CL printer available again

Printout on the system printer available once again

Date, time

Serious (positive, with match)

CL printer blocked

  • No response from system printer for past 4 minutes
  • Printer out of paper or switched off

Interface, interfaces/card number, port number, date, time

Serious (negative, with match)

Compatible PMS application

The external hotel management system (PMS application) is suitable for communicating with the communication server.

Date, time

critical (positive, with match)

Configuration template available

The missing configuration template for a Mitel SIP terminal is now available in the communication server file system.

Date, time

Serious (positive, with match)

Connection to IP remote management (SRM) failed

IP remote management connection set up (SRM = Secure IP Remote Management) has failed.

Cause parameter:1: Connection attempt failed, 2: Authentication failed, 3: File upload rejected

Cause, date, time

Normal (negative, with match)

Connection to IP remote management (SRM) restored

IP remote management connection has been (SRM = Secure IP Remote Management) successfully restored.

Date, time

Normal (positive, with match)

Connection to PMS system established

A connection with a hotel management system (PMS system) has now been successfully established.

Date, time

critical (positive, with match)

Connection to PMS system failed

An unsuccessful attempt was made to establish a connection with a hotel management system (PMS system).Reason: 1: Call rejected, 2: Destination unobtainable, 3: Destination busy, 4: Connection timeout, 5: Wrong address, 6: Unknown error

Error, date, time

critical (negative, with match)

CPU2 applications card Data communication out of service

Data communications with the CPU2 applications card have been interrupted for an unusually long period of time (> 1 hour) due to an error (after a Windows update or for other reasons).

Date, time

critical (negative, with match)

CPU2 applications card Data communications back in service

Data communications with the CPU2 applications card have been restored.

Date, time

critical (positive, with match)

Creation instance on backup communication server failed

The backup communication server was unable to create or modify a user or terminal instance with the received configuration data.

Note:

This event message is generated by the backup communication server.

Instance type (0: User, 1: terminal), user number or terminal ID, date, time

critical (negative, with match)

Creation instance on backup communication server successful

The backup communication server was able (following one or more previous failed attempts) to create or modify a user or terminal instance with the received configuration data.

Note:

This event message is generated by the backup communication server.

Instance type (0: User, 1: terminal), user number or terminal ID, date, time

critical (positive, with match)

CSTA sessions within the licence limit again

CSTA Sessions licences are now available again.

Number of licences, date, time

Serious (positive, with match)

CTI first party Connection established

The first-party link was (re-)established

User number, terminal ID, protocol type (0=ATPC3, 1=CSTA) date, time

critical (positive, with match)

CTI first party Connection lost

The first-party link was interrupted because the cycle signal is missing.

User number, terminal ID, protocol type (0=ATPC3, 1=CSTA) date, time

critical (negative, with match)

CTI third party: Connection established

The third-party link was (re-)established

IP address, protocol type (0=ATPC3, 1=CSTA), date, time

critical (positive, with match)

CTI third party: Connection lost

The third-party link was interrupted

Cause (0=Logoff, 1= missing cycle signal), IP address, protocol type (0=ATPC3, 1=CSTA) date, time

critical (negative, with match)

Definitive activation licence missing

The initial temporary activation of the communication server for a certain duration (e.g. 90 days) was started. After this period, the communication server switches to restricted operating mode.

Date, time

critical (negative, with match)

Definitive activation licence now present

A licence file with a definitive activation licence was uploaded.

Date, time

critical (positive, with match)

Dual Homing back within the licence limit

There are now enough licences available for registering SIP phones in the Mitel 6800/6900 SIP series on a backup communication server.

Note:

This event message is generated by the backup communication server.

Date, time

Serious (positive, with match)

E-mail successfully sent

The system has now successfully sent an e-mail.

Meaning of the parameter values, see table below.

Cause/action=0000, e-mail client, additional information, date, time

critical (positive, with match)

Emergency call ended

The emergency call has been confirmed by a responsible person.

Date, time

critical (positive, with match)

Emergency call started

An emergency number out of the public emergency number list has been dialled.

Note:

If an emergency number of the internal numbering plan has been dialled, no event message will be generated.

Dialled number (the first 4 digits), user number, terminal ID (if user number ? 0) or trunk group ID (if user number = 0), date, time

critical (negative, with match)

ESME reachable

The LAN connection between the SMSC and the ESME is now available

IP address, date, time

critical (positive, with match)

ESME unreachable

The LAN connection between the SMSC and the ESME is interrupted

IP address, date, time

critical (negative, with match)

Ethernet activated again

The overload on the Ethernet interface no longer exists. The interface has been reactivated.

Date, time

Normal (positive, with match)

Ethernet deactivated due to high load

The system has detected an overload on the Ethernet interface. The interface is temporarily deactivated.

Date, time

Normal (negative, with match)

External auxiliary power supply failed (Mitel 470 only)

The external auxiliary power supply to the communication server has failed. If the auxiliary power supply unit has been used for redundant operation, there are no short-term limitations. If the auxiliary power supply unit has been used to increase the power supply, the internal power supply unit overflow must be calculated.

Date, time

Serious (negative, with match)

External auxiliary power supply in service (Mitel 470 only)

The external auxiliary power supply to the communication server is working.

Date, time

Serious (positive, with match)

External event message destination not reachable

External signal destination not automatically reachable

Cause (0: Busy /1: Not available /2:(not used), 2: Barred /3: not defined), date, time

Serious (negative, with match)

External event message destination reachable

External signal destination is now reachable

Date, time

Serious (positive, with match)

Fan failure (Mitel SMBC only)

The fan is jammed or defective or the connection is no longer making contact.

  • Pa­rameter = 0: No more fans in operation.

    -> Risk of overheating: Replace defective fan.

Parameter, date, time

critical (negative, with match)

Fan failure (Mitel 470 only)

The fan is jammed or defective or the connection is no longer making contact.

  • Parameter 1 = 0: No more fans in operation.

    -> Risk of overheating: System shut down after 2 minutes.

    -> Replace both fans.

  • Parameter 1 = 1: Only one fan left in operation. Parameter 2 = Defective fan number

    -> System still running with only one fan.

    -> Replace defective fan.

Parameter 1, parameter 2, date, time

critical (negative, with match)

Fan in operation ( Mitel SMBC only)

The fan is back in service again after a failure.

  • Pa­rameter = 0: Fan back in service again.

Parameter, date, time

critical (positive, with match)

Fan in operation (Mitel 470 only)

The fan is back in service again after a failure.

  • Pa­rameter = 0: A fan is back in service again.

  • Parameter = 1: Second fan back in service again.

Parameter, date, time

critical (positive, with match)

FIAS command buffer full

The command buffer to the PMS interface is full.

Date, time

critical (negative, with match)

FIAS interface usable again

The command buffer to the PMS interface is back below the critical limit.

Date, time

critical (positive, with match)

Inactive radio unit port

Radio unit not responding Reason: 0: Startup running, 1: Not registered, 2: Various nodes, 3: Port not permitted, 4: Local power supply, 5: Not connected, 6: Port reset, 7: Startup error, 8: Unknown error

Card number, port number, radio unit ID/reason, date, time

Serious (negative, with match)

Incompatible PMS application

The external hotel management system (PMS application) is not suitable for communicating with the communication server.

PMS SW version, PMS interface version, PMS interface driver version, date, time

critical (negative, with match)

Incorrect or no wiring adapter (Mitel SMBC only)

There is no wiring adapter in the wiring adapter slot or the wiring adapter fitted is unsuitable.

Slot number, date, time

Critical (without match)

Insufficient bandwidth

An user in an AIN is trying to set up a connection and the bandwidth currently available with the WAN link is insufficient.

Link ID, WAN link name, available bandwidth in Kbit/s, date, clock

Serious (without match)

Internal event message destination not reachable

Local output blocked or not available

Cause (0: Busy /1: Not available /2:(not used), 2: Barred /3: not defined), date, time

Serious (negative, with match)

Internal event message destination reachable

Local output available once again

Date, time

Serious (positive, with match)

Internal power supply unit failed (Mitel 470 only)

The internal power supply unit of the communication server has failed. If the auxiliary power supply unit has been used for redundant operation, there are no short-term limitations. If the auxiliary power supply unit has been used to increase the power supply, the external power supply unit overflow must be calculated.

Date, time

Serious (negative, with match)

Internal power supply unit in service (Mitel 470 only)

The internal power supply unit of the communication server is in service.

Date, time

Serious (positive, with match)

IP address added to the DoS blocklist

A DoS attack has taken place beyond the maximum configured admissible registration attempts or transactions. The IP address concerned has been included in the blocklist and will remain blocked for a set period.

IP address, Cause (0: Registration / 1: Too many transactions / 2: No session / 3: modified message), date, time

Serious (negative, with match)

IP address changed: Regenerate TLS certificates

The IP address of the communication server has changed. The TLS certificates have to be regenerated. For terminals down circuit from a NAT without ALG the public NAT gateway address has to be configured.

Date, time

Serious (without match)

IP address removed from the DoS blocklist

An IP address added previously due to a DoS (Denial of Service) attack was again removed from the blocklist and is no longer blocked.

IP address, date, time

Serious (positive, with match)

IP phone: Connection lost

An IP system phone is no longer connected to the communication server.

User number, terminal ID, date, time

Serious (negative, with match)

IP phone: Connection re-established

An IP system phone has re-established the connection to the communication server.

User number, terminal ID, date, time

Serious (positive, with match)

IP system phone licence is now available

A sufficient number of licences is now available again for MiVoice 5361 IP / 5370 IP / 5380 IP.

Date, time

Serious (positive, with match)

Language file download failed

The downloading of a language file via FTP server for an MitelSIP terminal has failed.

Parameter 1: FTP server address, Parameter 2: Language file type and name, date, time

Serious (negative, with match)

Language file download successful

The downloading of a language file via FTP server for an Mitel SIP terminal has been successfully completed.

Parameter 1: FTP server address, Parameter 2: Language file type and name, date, time

Serious (positive, with match)

LCR on alternative network provider

Automatic switch from primary network provider to secondary network provider using LCR function.

Provider ID, date, time

Normal (without match)

Licence available for configured user (Mitel 470 and Virtual Appliance only)

This event message is generated, if all configured users have a user licence (which was not the case before).

Date, time

Serious (positive, with match)

Licence for integrated mobile/external phone available

A sufficient number of licences is now available again for integrated mobile/external phones.

Date, time

Serious (positive, with match)

Licence for PMS interface available

The Hospitality PMS Interface licence or a sufficient number of Hospitality PMS Rooms licences are now available.

Date, time

Serious (positive, with match)

Licence invalid, restricted operating mode 4 hours after restart

The system software loaded requires a software release licence. Without this licence the system software’s functionality is severely restricted 4 hours after the restart.

Date, time

Serious (with­out match)

Licence missing for configured user (Mitel 470 and Virtual Appliance only)

This event message is generated, if one or more configured users have no user licence.

Note:

To avoid a flood of messages this event message is generated only once (the first time a user is created without a user licence)

Date, time

Serious (negative, with match)

Licences for offline operations expired

The maximum period of 36 hours for the temporary licence activation has expired.

Date, time

Critical (without match)

Link to gateway satellite lost (Virtual Appliance only)

The communication server has lost the link to the gateway satellite. Without this link, the communication server switches to restricted operating mode after xx hours.

Number of hours until restricted operating mode, date, time

critical (negative, with match)

Link to gateway satellite restored (Virtual Appliance only)

The communication server has been able to restore the link to the gateway satellite.

Date, time

critical (positive, with match)

Link to the licence server (SLS) has failed (Virtual Appliance only)

It has been impossible for a long time to set up a link to the licence server. The system switches to restricted mode after a variable timeout (max. 72 hours).

Date, time

critical (negative, with match)

Link to the licence server (SLS) has restored (Virtual Appliance only)

It has been possible to restore a link to the licence server.

Date, time

critical (positive, with match)

Local supply error on radio unit

Local power supply of a SB-4+ / SB-8 / SB-8ANT radio unit failed or unavailable

Card number, port number, date, time

critical (negative, with match)

Local supply on radio unit available

Local power supply of a SB-4+ / SB-8 / SB-8ANT is now again available

Card number, port number, date, time

critical (positive, with match)

Mains voltage failure

Event message once mains power is restored

  • Mains power has failed more frequently than entered in the trigger table

Date, time

Serious (without match)

Malfunction

A hardware or software error has occurred. The error ID can help Support to pinpoint the possible cause of the error.

Error ID, date, time

Serious (without match)

MiCollab: Terminal limit has been reached

A MiCollab terminal could not be linked to a user because a limit has been reached (reason).

reason = 0: Too much terminals per system

reason = 1: Too much terminal per user

reason = 2: Too much MiCollab clients per user

User number, reason, date, time

Serious (negative, with match)

MiCollab: Within the terminal limits again

A MiCollab terminal could now be linked to a user because it is within a limit again (reason).

reason = 0: Terminals per system OK again

reason = 1: Terminal per user OK again

reason = 2: MiCollab clients per user OK again

User number, reason, date, time

Serious (positive, with match)

Mitel Dialer within the licence limit again

Mitel Dialer user licences are now available again.

Date, time

Serious (positive, with match)

Mitel SIP terminals within the licence limit again

Mitel SIP Terminals and Mitel 8000i Video Options licences are now available.

Parameter 1=1: Mitel SIP Terminals licence, Parameter 2=1: Mitel 8000i Video Options licence, date, time

Serious (positive, with match)

Monitor event

Monitor event

Monitor Type, Date, Time

Normal (without match)

No configuration template

A configuration template for a Mitel SIP terminal is missing in the communication server file system. Without the configuration template, no configuration file can be generated for this terminal type.

No configuration template, date, time

Serious (negative, with match)

No DECT DSP channels available

DECT channels on DSP-0x overloaded

Date, time

Normal (without match)

No DTMF receiver available for integrated mobile/external phones

A permanent DTMF receiver (for detection suffix dialling function codes) could not be assigned to an integrated mobile/external phone with enhanced functionality.

BCS Ref., date, time

Serious (without match)

No other system clone detected (Virtual Appliance only)

The clone detection service on the licence server (SLS cloud) could not find any other clone (system with the same EID) for a long time (24 hours).

Date, time

critical (positive, with match)

No response from network

No answer to Call Setup on BRI-T/PRI interface

Port number of the exchange line circuit, date, time

Normal (without match)

No response from user

No answer to incoming DDI call from user on S bus or DSI

DDI No., date, time

Normal (without match)

Node: Connection lost

A node is not connected to the Master for a certain amount of time (configurable).

Node number, date, time

critical (negative, with match)

Node: Connection re-established

A node is reconnected with the Master for a certain amount of time (configurable) after an interruption.

Node number, date, time

critical (positive, with match)

Not enough licences for integrated mobile/external phones

The connection set­up with an integrated mobile/external phone has failed because the number of configured mobile/external phones is greater than the number of licences available. All the integrated mobile/external phones remain blocked until a sufficient number of licences are available.

Number of licences, number of configured mobile/external phones, date, time

Serious (negative, with match)

NTP: Time synchronisation failed

Time synchronization via the NTP server (NTP = Network Time Protocol) has failed.

Date, time

Serious (negative, with match)

NTP: Time synchronisation re-established

Time synchronization via the NTP server (NTP = Network Time Protocol) has been restored.

Date, time

Serious (positive, with match)

Outgoing call rejected

Call rejected by the network

  • On any line: error code 34

  • On required line group:error code 44

Port number of the exchange line circuit, cause, date, time

Normal (without match)

Overheat (Mitel SMBC only)

The temperature in­side the communication server is too high. The appropriate measures must be taken immediately to improve the heat dissipation, e.g. by providing the required clearances, lowering the ambient temperature or installing the fan from the rack-mounting set (Mitel 430 only).

critical (negative, with match)

Card number, temperature, date, time

Overheat (Mitel 470 only)

The temperature inside the communication server is too high. Appropriate measures must be taken immediately to improve heat dissipation. Measures are automatically adopted, depending on where the overheating occurs:

FXO and FXS interface card:

  • the ports are deactivated in groups of 4 ports.

  • Once they have cooled down below a defined card-specific value, the ports are automatically reactivated group by group.

CPU2 applications card

  • The card will be completely deactivated. Once it has cooled down below a defined value, the card is automatically reactivated.

Internal power supply unit PSU2U or call manager card CPU1:

  • the communication server will be shut down completely.

Note:
  • To prevent the system from overheating, no more than 30% of the FXS ports should be active simultaneously per 32FXS card and no more than 50 FXS ports per system.
  • PRI, BRI and DSI cards do not have temperature sensors and are therefore never deactivated due to overheating.

Card number, temperature, date, time

critical (negative, with match)

Overload detected on USB port (CPU2) (Mitel 470 only)

A (current) overload was detected on one of the USB interfaces on the applications card (CPU).

Note:

The maximum current input at the USB interfaces varies.

Date, time

Normal (without match)

Port out of service

A port previously in operation has stopped functioning.

Number of the slot, relevant port number, date, time

Serious (without match)

Possible clone detected for your system (Virtual Appliance only)

The clone detection service on the licence server (SLS cloud) has detected a possible clone (system with the same EID).

Date, time

critical (negative, with match)

QSIG licence limit reached

Maximum number of licensed outgoing connections with QSIG protocol exceeded

Route number, user number, date, time

Serious (without match)

Radio unit port active

The radio unit is responding again

Card number, port number, date, time

Serious (positive, with match)

Register error

  • Card not fitted
  • Card not logged on
  • Card defective

Card number, date, time

Normal (without match)

Remote maintenance disabled

Remote maintenance has been deactivated

Date, time

Normal (positive, with match)

Remote maintenance enabled

The remote maintenance has been activated (The report is output unfiltered on local destinations).

Date, time

Normal (negative, with match)

Restart of applications card CPU2 executed

The restart of applications card CPU2 was executed successfully.

Date, time

critical (positive, with match)

Restart of applications card CPU2 required

The system has detected that a manual restart of the applications card CPU2 is required (e. g. for a security update).

Date, time

critical (negative, with match)

Restricted operating mode disabled

Restricted mode could be disabled again.

Date, time

critical (positive, with match)

Restricted operating mode enabled (not valid for Virtual Appliance)

The communication server has switched to restricted mode. Cause: 0: No valid licence

Cause, date, time

critical (negative, with match)

Restricted operating mode enabled (Virtual Appliance only)

The communication server has switched to restricted mode. Cause: 0: No valid licence. 1: Link to gateway satellite lost. 2: Max. duration without link to licence server reached. 3: Your system clone confirmed. 4: Licence check mode mismatch in SLS and MiVo400. 5: Support mode enabled.

Cause, date, time

critical (negative, with match)

Satellites missing after supervision time

After an AIN update (Master and all satellites) some satellites no longer have a connection to the Master.

Total satellites missing, Satellites rolled back, Date, Time

Serious (without match)

Send e-mail failed

The system was unable to send an e-mail because an error occurred.

Meaning of the parameter values, see table below.

Cause/action, e-mail client, additional information, date, time

critical (negative, with match)

SIMPLE/MSRP back within the licence limit

There are now enough licences available for using the MSRP and/or SIMPLE protocol for users.

Date, time

Serious (positive, with match)

SIP account available

The SIP account has successfully registered with the SIP provider.

Provider, account, date, time

critical (positive, with match)

SIP account not available

The SIP account cannot register with the SIP provider for a certain reason (0: Provider unobtainable / 1: no permission). The event is triggered only if the parameter Registration required is configured to Yes.

Provider, account, date, time

critical (negative, with match)

SMS gateway reachable

External SMS gateway again reachable

Date, time

critical (positive, with match)

SMS gateway unreachable

External SMS gateway unobtainable by network provider or incorrectly configured

Date, time

critical (negative, with match)

Software upgrade IP system phone failed

The software update of an MiVoice 5361 IP / 5370 IP / 5380 IP has failed for the stated reason.

User number, terminal ID, reason, date, time

critical (negative, with match)

Software upgrade IP system phone successful

The software update of an MiVoice\ 5361 IP / 5370 IP / 5380 IP has now been successfully completed after unsuccessful attempt(s).

User number, terminal ID, date, time

critical (positive, with match)

Software upload

During an upload in system status:

  • Update running
  • Supervision running
  • Normal operation

Parameter 1:

  • 0: "New communication server software loaded, starting...",
  • 1: New communication server software crashed, roll­back performed

  • 3: New communication server software started and running well

Date, time

Normal (without match)

Standard SIP terminals within the licence limit again

SIP Terminals and Video Terminals licences are now available.

Parameter 1=1: SIP Terminals licence, Parameter 2=1: Video Terminals licence, date, time

Serious (positive, with match)

SX-200 call data record management system: Connection established

The connection to the SX-200 call data record management system has been successfully established.

Date, time

critical (positive, with match)

SX-200 call data record management system: Connection lost

The connection to the SX-200 call data record management system has been lost.

Date, time

critical (negative, with match)

SX-200 hotel management system: Connection established

The connection to the SX-200 hotel management system has been successfully established.

Date, time

critical (positive, with match)

SX-200 hotel management system: Connection lost

The connection to the SX-200 hotel management system has been lost.

Date, time

critical (negative, with match)

SX-200 voice mail management system: Connection established

The connection to the SX-200 voice mail management system has been successfully established.

Date, time

critical (positive, with match)

SX-200 voice mail management system: Connection lost

The connection to the SX-200 voice mail management system has been lost.

Date, time

critical (negative, with match)

Synchronisation loss on trunk

A BRI/PRI interface entered in the clock pool has lost the system clock

Port number, date, time

Serious (negative, with match)

Synchronisation re-established

Synchronization with the network has been restored on at least one BRI/PRI interface.

Date, time

Serious (positive, with match)

Synchronisation with backup communication server failed

The primary communication server was unable to transmit the configuration data to the backup communication server.

Note:

This event message is generated by the primary communication server.

Backup communication server ID, date, time

critical (negative, with match)

Synchronisation with backup communication server successful

The primary communication server was able (following one or more previous failed attempts) to transmit the configuration data to the backup communication server.

Note:

This event message is generated by the primary communication server.

Backup communication server ID, date, time

critical (positive, with match)

Synchronization on trunk re-established

A BRI/PRI interface entered in the clock pool has been successfully re-synchronized with the system clock.

Port number, date, time

Serious (positive, with match)

System memory usage below the critical range again

The memory usage in the file system for a specific purpose has again fallen below a defined (Serious severity level) or critical (Critical severity level) value.

Purpose (file type ID):0: File system, 1: Application, 2: Crash-Log, 3: Monitor-Log, 4: Announcement service, 5: Voice mail, 6: Music on hold, 7: Data backup, 8: Hospitality/Accommodation, 9: User folder

File type ID, memory usage in %, date, time

Serious / Critical (positive, with match)

System memory usage over the critical range

The memory usage in the file system for a specific purpose has exceeded a defined (Serious severity level) or critical (Critical severity level) value.

Purpose (file type ID):0: File system, 1: Application, 2: Crash-Log, 3: Monitor-Log, 4: Announcement service, 5: Voice mail, 6: Music on hold, 7: Data backup, 8: Hospitality/Accommodation, 9: User folder

File type ID, memory usage in %, date, time

Serious / Critical (negative, with match)

System overload

Network access attempted when all lines are seized or the system is overloaded.

Route number, user number, date, time

Normal (without match)

System phone in service again

A system phone on the DSI bus is ready for operation again.

Card number, port number, user number, date, time

critical (positive, with match)

System phone out of service

A system phone on the DSI bus is defective or was disconnected.

Card number, port number, user number, date, time

critical (negative, with match)

Temperature within normal range again

Following overheating, the temperature inside the communication server is back in the normal operating range.

Card number, temperature, date, time

critical (positive, with match)

Temporary activation expires on

Reminder of the missing, definitive activation licence following connection setup with the communication server.

Expiration date [DD.MM.YYYY], date, time

Serious (without match)

Terminal power supply: Overload (Mitel 470 only)

Rated output slightly exceeded for > 4 s.

Date, time

critical (negative, with match)

Terminal power supply: Shutdown (Mitel 470 only)

Rated output clearly exceeded for 4 s.

Date, time

critical (negative, with match)

Terminal power supply: Switching back on (Mitel 470 only)

The power supply to the terminals was switched back on after deactivation due to overflow.

Date, time

critical (positive, with match)

Terminal power supply: Within normal range again (Mitel 470 only)

The power supply to the terminals is back in the normal rated output range following a slight, preceding overflow.

Date, time

critical (positive, with match)

Test event message

The configuration of message destinations can be tested with this event message.

Date, time

Serious (without match)

The communication server has been restarted

The communication server was restarted manually or automatically due to an error.

Date, time

Critical (without match)

The licence limit for BluStar clients has been reached.

A BluStar client was unable to register because there are too few licences for this client type.

Parameter 1: 0 (not used)

Licence type: 0 and 1: (not used), 2: BluStar CTI, 3: BluStar Softphone, 4: BluStar video option, 5: BluStar Presence option

Parameter 1, licence type, total purchased licences, date, time

Serious (negative, with match)

The licence limit for CSTA sessions has been reached

An application is un­able to set up a CSTA session to monitor/check a terminal because there are too few CSTA Sessions licences available.

Max. number of licences, date, time

Serious (negative, with match)

The licence limit for Dual Homing has been reached

A SIP phone in the Mitel 6800/6900 SIP series has attempted to register on a backup communication server and not enough licences are available.

Note:

This event message is generated by the backup communication server.

Date, time

Serious (negative, with match)

The licence limit for Mitel Dialer has been reached

Mitel Dialer could not be linked to a user because too few licences are available.

Total purchased licences, date, time

Serious (negative, with match)

The licence limit for Mitel SIP terminals has been reached

A Mitel SIP terminal is unable to register or use the video functionality because there are too few Mitel SIP Terminals or Mitel 8000i Video Options licences available.

Parameter 1=1: Missing Mitel SIP Terminals licence, Parameter 2=1: Missing Mitel 8000i Video Options licence, Parameter 3=3: Max. number of licences, date, time

Serious (negative, with match)

The licence limit for SIMPLE/MSRP has been reached

A third-party application wishes to use the MSRP and/or SIMPLE protocol for a user, but not enough licences are available.

Date, time

Serious (negative, with match)

The licence limit for standard SIP terminals has been reached

A standard SIP terminal is unable to register or use the video functionality because there are too few SIP Terminals or Video Terminals licences available.

Parameter 1=1: Missing SIP Terminals licence, Parameter 2=1: Missing Video Terminals licence, Parameter 3=3: Max. number of licences, date, time

Serious (negative, with match)

TLS certificate expires soon

A TLS certificate for a SIP node or SIP endpoint is about to expire (Serious severity level) or has just expired (Critical severity level) and needs to be renewed.If the endpoint type is = 0 (Mitel), then is parameter 2 = node ID.If the endpoint type is = 1 (3rd party), then the remaining parameter data contains the first eleven characters of the certificate name.

Type of endpoint (0: Mitel, 1: 3rd party), node ID or certificate name, date, time

Serious / Critical (without match)

TLS certificate update failed

The update of the TLS certificate for an SIP node or SIP endpoint via FTP has failed and needs to be renewed manually.If the endpoint type is = 0 (Mitel), then is parameter 2 = node ID.If the endpoint type is = 1 (3rd party), then the remaining parameter data contains the first eleven characters of the certificate name.

Type of endpoint (0: Mitel, 1: 3rd party), node ID or certificate name, date, time

 

critical (negative, with match)

TLS certificate update successful

A TLS certificate for a SIP node or SIP endpoint was successfully renewed.If the endpoint type is = 0 (Mitel), then is parameter 2 = node ID.If the endpoint type is = 1 (3rd party), then the remaining parameter data contains the first eleven characters of the certificate name.

Type of endpoint (0: Mitel, 1: 3rd party), node ID or certificate name, date, time

critical (positive, with match)

TLS certificate was generated: Upgrade non-Mitel endpoints now

A TLS certificate has been generated. If generation is manual, the certificate must be imported manually into the Mitel SIP nodes. The certificate must always be imported manually on all non-Mitel nodes and non-Mitel endpoints.

Date, time

Normal (without match)

TLS server certificate: Validation failed

While a TLS connection is established the validation of the certificate of the TLS server failed.

Service, TCP port, reason, date, time

critical (negative, with match)

TLS server certificate: Validation successful

The validation of the certificate of the TLS server was successful.

Service, TCP port, date, time

critical (positive, with match)

Too few FoIP channels

Setting up a fax connection via T.38 failed because no FoIP channel is available.

Available FoIP channels on node

Serious (without match)

Too few licences for IP system phones

A MiVoice 5361 IP / 5370 IP / 5380 IP was unable to register because there are too few IP system phone licences.

Date, time

Serious (negative, with match)

Too few licences for PMS interface

Either the Hospitality PMS Interface licence is missing or the number of Hospitality PMS Rooms licences available is insufficient.

Number of licensed rooms, number of configured rooms, date, time

Serious (negative, with match)

Too few VoIP channel licences

Connection setup failed because the licence limit for simultaneously active VoIP channels has been reached.

No. of licensed VoIP channels, Date, Time

Serious (without match)

Too few VoIP channels

An user is trying to set up a connection that requires one or more VoIP channels which are currently not available.

Available VoIP channels on this node, date, time

Normal (without match)

Too many errors with the same ID

An unusual amount of errors (more than 50 per hour) with the same error ID have occurred.

Error ID, date, time

Normal (without match)

Too many event messages

Number of message types exceeds limit entered in the table on:

  • "Synch. "Synch.loss on BRI/PRI"
  • "Outgoing Call Rejected"
  • "No response from network"

Date, time

Normal (without match)

Too much user data

System capacity exceeded

Date, time

Critical (without match)

Total synchronization loss

Network synchronisation has failed on all BRI/PRI interfaces

Date, time

Serious (negative, with match)

Trial licence expired

The duration for which a trial licence can be used for a specific feature has expired and there is no valid licence.

Licence ID, date, time

Serious (without match)

USER EVENT MESSAGE

With *77[nnnn] from a terminal

nnnn [0000...99999], user number, date, time

Serious (without match)

User memory usage below the critical range again

The memory usage in the file system for a specific user has again fallen below a defined (Serious severity level) or critical (Critical severity level) value.

User number, memory usage in %, date, time

Serious / Critical (positive, with match)

User memory usage over the critical range

The memory usage in the file system for a specific user has exceeded a defined (Serious severity level) or critical (Critical severity level) value.

User number, memory usage in %, date, time

Serious / Critical (negative, with match)

Wake-up call failed

The room wake-up call was not answered

Room No., date, time

Normal (negative, with match)

Wake-up order confirmed

The room wake-up call has now been answered

Room No., date, time

Normal (positive, with match)

Table 2. Meaning of the parameter values for the event message Send e-mail failed
  Parameter 1 (XXYY)   Parameter 2: Parameter 3:
Value Reason (XX) Action (YY)2 E-mail client Additional info depending on the e-mail client (XXYY)

00

Not defined

Not defined

Not defined

 

01

E-mail memory full

Connection set up to SMTP server

Voice mail

XX: Mailbox ID

YY: Message ID

02

SMTP server access data invalid

Extended registration on SMTP server

Auto backup

 

03

SMTP client cannot set up a connection to the server

Registration on SMTP server

Call recording

User number

04

Authentication failed

Transmission of e-mail address

Event message

 

05

Temporary negative answer from SMTP server

Transmission of e-mail recipient address Call logging for hospitality

   

06

Temporary negative answer from SMTP server

Prepare data transmission

Configuration files

XX: User ID

YY: Terminal ID

07

No answer from SMTP server

Data transmission in progress

   

08

E-mail attachment not found

End data transmission

   

09

Invalid host, domain or IP address on the communication server

Prepare authentication (LOGIN)

   

10

E-mail text too long (body)

User name authentication (LOGIN)

   

11

E-mail attachment too large

Password authentication (LOGIN)

   

12

Format of e-mail attachment not supported

Authentication (PLAIN)

   

13

No e-mail recipient address

Prepare encrypted authentication (CRAM-MD5)

   

14

Invalid e-mail recipient address

Encrypted authentication (CRAM-MD5)

   

15

Invalid e-mail sender address

Preparing to send next e-mail

   
Note:

In the System events / Settings / Event tables"Event tables" view, you can set for each event and according to destination, how often an event message may appear for each period until it is issued on the configured destination.

1 The node is also always indicated in an AIN.
2 Action carried out by the SMTP client at the point when the error occurred.